Home
>
Hardware
>
Model 5100
OVERVIEW
FEATURES
OPTIONS
SPECIFICATIONS
The Model 5100 Demand Test System is a multi-position testboard designed to verify the proper operation and registration of mechanical, thermal, and electronic demand registers. With the pulse initiator option, contact devices within the meter(s) under test may also be verified.
Designed for flexibility, the 5100 functions as either a time run or programmable standard revolutions test system. Meter socket bypassing allows the testboard to run with less than a full complement of meters. Meter form numbers must be identical for each run, but register multipliers (and Mp or C/R if optionally equipped) can be individually entered for each test station. Testboard operation at end-of-test is also programmable, including maintaining voltage for solid state demand registers.
The Model 5100 is a PC based system that provides an operator interface that is easy to learn and use, yet powerful and flexible. Total testboard control is obtained through a standard ASCII keyboard. All setup information, test parameters, and test results are clearly displayed on a high-resolution SVGA color monitor. The operator's job is greatly simplified by the use of single key commands, programmable default tables, and on-line user help screens
FEATURES
Closed link testing
200 Amp test capacity
Radian Research™ RD-20 standard - easily removed for testing
Dual testing modes - time run or standard revolutions
Energized meter "warm up" function
"During Test" demand calculation and display (as low as 100 mw resolution)
Programmable end-of-test setup (beep only, de-energize voltage, de-energize current, de-energize both)
Watt-Net™ data acquisition local area network compatible
Default setup table for each meter form
Provided PC:
2.6 GHz Processor, 3.5" Floppy Disk Drive • 40 GB HD, 128 MB RAM, 2 USB Ports, Printer Port, CD ROM, • 21" SVGA Monitor - .26 dot pitch (1600 X 1200 - 256 colors) • Software Package: Windows™ XP Professional, 101 Key Keyboard, Mouse
Individual register multiplier entry for each station
Individual MP or C/R entry for each station (for KYZ pulse initiator verification)
Floor standing configuration with writing ledge and casters
All aluminum construction
Smart Socket™
OPTIONS
Additional test bays - 3 test stations per bay (available in 9, 12, and 15 stations)
Barcode reader with software
Bottom connected single stator adapter
Bottom connected multiple stator adapter
Optional test capability for Q and VA functions
PC hardware upgrades available. Contact your sales representative
SPECIFICATIONS
Source:
3 PH 208 Wye or 240 Delta 60 Hz (specify with order)
Number of test stations:
Twelve (12) stations on basic unit
Test potential:
60V – 540V
Test power factor:
0 - 359 degrees lagging
Test currents:
0.1A to 200A
Potential clips:
Closed for test
Meter forms tested:
1S, 2S, 3S, 4S, 5S, 6S, 8S, 9S, 10S, 12S, 13S, 14S, 15S, 16S, 25S, 26S, 29S, 35S, 36S, 45S, 46S, 56S, or 66S
Test sockets:
Smart Socket™
Standard:
Type RD-20 electronic/Radian Research™
Demand test type:
Time run (Hrs, Mins, and Secs) or specific meter disk revolutions (1-9999)
System accuracy:
• Self contained meters: KW +/-0.20%
• Transformer rated meters: KW +/-0.10%
Dimensions:
71.25"H X 33”D cabinet model
• Nine Stations 62” Wide
• Twelve Stations 84” Wide
• Fifteen Stations 104” Wide
• Writing Ledge 30" Above Base
Warranty:
Two (2) year limited warranty inside the United States on all parts and labor • One (1) year limited warranty overseas on all parts and labor • 90 days on optional barcode scanner • PC subject to manufacturer’s warranty
Copyright © 2006 Watthour Engineering Co., Inc. All rights reserved.
333 Cross Park Drive, Pearl, MS 39208 • Telephone: 601.933.0900 • FAX: 601.933.0901